Repsol Empatem CC-30 GS

Translation of the original Spanish. In case of a discrepancy, the Spanish original prevails
Description and Recommendations
A hydrogenated base oil (from Hydrocraking) with special additives that provide the properties required in continuous steel casting. Empatem CC-30 GS is particularly suitable for lubricating theextraction from the mould of cast steel prepared in the crucible in cases where minimum carbonaceous residue is needed.
Properties
Provides an excellent finish on the ingots. Minimum sulphur content, meaning that possible toxicity of machine operators is avoided, as is corrosion of the moulds.Very low aromatics, reducingbothersome smoke to a minimum. Good lubricating power for the requirements it is subjectto.Minimum losses due to volatility.Very low tendency to form carbonaceous residue.
Technical characteristics
- |
UNITS |
METHOD |
VALUE |
Appearance |
- |
- |
Glossy and transparent |
Colour |
- |
ASTM D 1500 |
1,5 |
Density at 15oC |
g/ml |
ASTM D 4052 |
0,840 |
Viscosity at 40oC |
cSt |
ASTM D 445 |
32 |
Viscosity at 100oC |
cSt |
ASTM D 445 |
6 |
Viscosity rate |
- |
ASTM D 2270 |
135 |
Flammability V/A |
oC |
ASTM D 92 |
225 |
Aniline point |
oC |
ASTM D 611 |
95 |
Pour point |
oC |
ASTM D 97 |
-20 |
Saponification rate |
mg KOH/g |
ASTM D 94 |
14 |
Noack volatility, 1hr at 150oC |
- |
DIN 51581 |
2 |
Ramsbottom carbon |
% |
ASTM D 5424 |
0,02 |
Cu corrosion, 3hr at 100oC |
- |
ASTM D 130 |
1a |
Overview
Bulk
Hazard identification
This product is not classified as toxic or hazardous under current legislation.
Handling
Minimum precautions should be taken to avoid prolonged contact with the skin. The use of gloves, visors or glasses is recommended to avoid splashes.
Health and safety risks.
Inhalation: As this product has low volatility, the risk of inhalation is minimal. Ingestion: Do not make an affected person vomit. Supply water. Get medical help. Contact with the skin: Wash thoroughly with soap and water.Eyes: Wash thoroughly with water.General measures: Get medical help.
Fire-fighting measures
No special measures required.Extinction: Foams, dry chemicals, CO2, water spray. Do not apply a jet of water directly, as it could spread the product.
Environmental precautions
Danger of physical pollution if spilt (water, coastlines, soil, etc.) due to its floatability and oily consistency that may harm flora and fauna on contact. Prevent the material from entering the water supply. Decontamination and cleaning: Treat as an accidental oil spillage. Avoid dispersion using
mechanical barriers and remove with physical or chemical elements.
|
|